[rank_math_breadcrumb]

Alternator A.R.K5ES

A.R.K5ES Alternator – Brushless, PMG Excited, and High-Efficiency Industrial Alternator

The A.R.K5ES alternator, developed by Arken Power Solutions, is a high-efficiency three-phase, brushless synchronous alternator equipped with a PMG excitation system and MX341 AVR for superior voltage regulation and transient response. Engineered for industrial, rental, and standby generator applications, it ensures voltage stability within ±1% and total harmonic distortion below 5%. Featuring Class H insulation, IP23 protection, and a rigid steel frame, the A.R.K5ES provides durability, low maintenance, and an impressive 95.3% efficiency. Fully compliant with IEC60034, BS5000, NEMA MG1-22, CSA C22.2-100, and ISO9001, this alternator is ideal for prime, standby, and mobile power systems operating in demanding conditions.

Alternator Model

A.R.K5ES

50Hz (kVA)

565

60Hz (kVA)

656
Control SystemSELF EXCITED
A.V.R.MX341 WITH PMG
Voltage Regulation ± 1.0 %
Sustained Short Circuit>300% OF RATED CURRENT
Rated Power Factor0.8

Electrical Performance

  • Type: Three-phase, brushless, self-excited synchronous alternator with PMG excitation

  • Frequency: 50 / 60 Hz

  • Power Factor: 0.8

  • Voltage Range: 380/220V – 480/277V (configurable in star, delta, or parallel star)

  • Voltage Regulation: ±1.0%

  • Total Harmonic Distortion (THD): <5% (balanced linear load), <1.5% (no load)

  • Sustained Short Circuit Current: >300% rated current for 10 seconds

  • Efficiency: Up to 95.3%

  • Overload Capacity: 110% for one hour in a six-hour cycle

  • Telephone Harmonic Factor (THF): <2%

  • Telephone Interference Factor (TIF): <50

  • Short Circuit Ratio (1/Xd): 0.09 typical

  • Reactances (Per Unit at Rated kVA):

    • Xd (Synchronous): 2.83–3.53

    • X’d (Transient): 0.12–0.17

    • X’’d (Subtransient): 0.09–0.12

    • Xq (Quadrature): 2.21–2.82

    • X’’q (Quadrature Subtransient): 0.24–0.34

    • X₂ (Negative Sequence): 0.16–0.23

    • X₀ (Zero Sequence): 0.06–0.10

  • Time Constants:

    • Transient (T’d): 0.08 s

    • Subtransient (T’’d): 0.012 s

    • Armature (Ta): 0.019 s

    • Open Circuit Field (T’do): 2.5 s

Construction & Design

  • Insulation Class: H (125°C rise at 40°C ambient)

  • Protection: IP23 (optional IP44 with power reduction)

  • Cooling System: Self-ventilated air cooling (1.035 m³/s @50Hz, 1.312 m³/s @60Hz)

  • Frame: Rigid steel structure with cast aluminum front and rear covers

  • Winding: Double-layer stator winding, 2/3 pitch design eliminates triple harmonics

  • Rotor: Damped rotor with high mechanical balance (BS6861 compliant)

  • Bearings:

    • Drive End: 6220-2RS (sealed-for-life ball bearing)

    • Non-Drive End: 6314-2RS (sealed-for-life ball bearing)

  • Overspeed Capability: 120% of rated speed (2250 rpm)

  • Leads: 12 reconnectable leads (star, delta, parallel star)

  • Inertia (WR²):

    • Single Bearing: 8.98 kg·m²

    • Double Bearing: 8.70 kg·m²

  • Weight:

    • Rotor: 617 kg (single bearing) / 588 kg (double bearing)

    • Stator: 722 kg

    • Complete Alternator: 1543 kg (single bearing) / 1535 kg (double bearing)

  • Shipping Weight: 1635 kg (50Hz) / 1625 kg (60Hz)

  • Packing Dimensions: 166 × 87 × 124 cm

Regulation & Control

  • Excitation System: PMG excitation with brushless design

  • AVR Model: MX341 (standard), optional SX460, SX440, AS440, MX321

  • Voltage Regulation Accuracy: ±1.0%

  • Parallel Operation: Supported (AVR-dependent)

  • Low-Speed Voltage Drop Protection: Standard feature

  • RFI Suppression: Complies with BS EN 61000-6-2 & BS EN 61000-6-4, VDE 0875G/N

  • Protection Features:

    • Stator winding and bearing overheat protection

    • Anti-condensation heater (optional)

  • Standards Compliance: IEC60034, GB755, BS5000, NEMA MG1-22, CSA C22.2-100, AS1359

  • Certification: ISO9001 Quality Management System

Environmental Parameters

  • Operating Temperature: –15°C to +40°C

  • Relative Humidity: Up to 95% (non-condensing)

  • Altitude: Up to 1000 m without derating

  • Cooling Air Requirement: 1.035 m³/s (50Hz), 1.312 m³/s (60Hz)

  • Noise & Vibration: Balanced per BS6861 standards

Performance Summary

  • Efficiency Range: 94.7–95.3% across load range

  • Voltage Dip (Transient Load): ≤25% at 0.8 PF

  • Recovery Time: <0.5 seconds

  • Locked Rotor Motor Starting: >300% of rated current

  • Applications: Prime power, standby, rental, telecom, mobile power, refrigeration, lighting tower, and railway generator systems

Datasheet