[rank_math_breadcrumb]

Alternator A.R.K4FG

A.R.K4FG Alternator – Brushless, PMG Excited, and High-Efficiency Industrial Power Generation

The A.R.K4FG alternator, developed by Arken Power Solutions, is a premium three-phase, brushless synchronous alternator with a PMG excitation system and MX341 AVR, providing exceptional voltage stability and high transient response. Designed for continuous industrial operation, it delivers ±1% voltage regulation and less than 5% total harmonic distortion (THD), ensuring clean and consistent power for critical loads. Built with Class H insulation, IP23 protection, and a rigid steel frame, it achieves up to 94.2% efficiency, offering superior performance for both prime and standby applications. Fully compliant with IEC60034, BS5000, NEMA MG1-22, CSA C22.2-100, and ISO9001, the A.R.K4FG alternator is engineered for durability and high reliability in industrial, telecom, rental, and mobile generator systems.

Alternator Model

A.R.K4FG

50Hz (kVA)

400

60Hz (kVA)

425
Control SystemSELF EXCITED
A.V.R. MX341 WITH PMG
Voltage Regulation ± 1.0 %
Sustained Short Circuit >300% OF RATED CURRENT
Rated Power Factor0.8

Electrical Performance

  • Type: Three-phase, brushless, self-excited synchronous alternator with PMG excitation

  • Frequency: 50 / 60 Hz

  • Power Factor: 0.8

  • Rated Voltage: 380/220V – 480/277V (configurable in star, delta, or parallel star connection)

  • Voltage Regulation: ±1.0%

  • Total Harmonic Distortion (THD): <5% (balanced linear load), <1.5% (no load)

  • Sustained Short Circuit Current: >300% of rated current for 10 seconds

  • Efficiency: Up to 94.2% at full load

  • Telephone Harmonic Factor (THF): <2%

  • Telephone Interference Factor (TIF): <50

  • Short Circuit Ratio (1/Xd): 0.09 typical

  • Overload Capacity: 110% for one hour in six-hour cycles

  • Reactances (Per Unit at Rated kVA):

    • Xd (Synchronous): 2.17–3.21

    • X’d (Transient): 0.12–0.17

    • X’’d (Subtransient): 0.09–0.12

    • Xq (Quadrature): 1.66–2.84

    • X’’q (Quadrature Subtransient): 0.25–0.39

    • X₂ (Negative Sequence): 0.16–0.26

    • X₀ (Zero Sequence): 0.06–0.08

  • Time Constants:

    • Transient (T’d): 0.08 s

    • Subtransient (T’’d): 0.019 s

    • Armature (Ta): 0.018 s

    • Open Circuit Field (T’do): 1.7 s

  • Waveform Distortion: <1.5% (no load), <5% (balanced linear load)

Construction & Design

  • Insulation Class: H (125°C rise at 40°C ambient)

  • Protection: IP23

  • Cooling System: Self-ventilated air cooling (0.486 m³/s @50Hz, 0.580 m³/s @60Hz)

  • Frame Structure: Rigid steel frame with cast aluminum front and rear covers

  • Winding: Double-layer stator winding, 2/3 pitch design to eliminate triple harmonics

  • Rotor: Damped rotor with dynamic balancing (BS6861 compliant)

  • Bearings:

    • Drive End: 6317 (sealed-for-life ball bearing)

    • Non-Drive End: 6314 (sealed-for-life ball bearing)

  • Overspeed Capability: 120% of rated speed (2250 rpm)

  • Leads: 12 reconnectable leads (star, delta, parallel)

  • Moment of Inertia (WR²):

    • Single Bearing: 5.43 kg·m²

    • Double Bearing: 5.23 kg·m²

  • Weight:

    • Complete Alternator: 1160 kg

    • Rotor: 463 kg

    • Stator: 535 kg

  • Shipping Weight: 1775 kg (50Hz) / 1780 kg (60Hz)

  • Packing Dimensions: 155 × 87 × 107 cm (50Hz) / 156 × 87 × 107 cm (60Hz)

Regulation & Control

  • Excitation System: PMG excitation with brushless design

  • AVR Model: MX341 (standard), optional SX460, SX440, AS440, MX321

  • Voltage Regulation Accuracy: ±1.0%

  • Parallel Operation: Supported (AVR-dependent)

  • Low-Speed Voltage Drop Protection: Standard feature

  • RFI Suppression: Complies with BS EN 61000-6-2 and BS EN 61000-6-4, VDE 0875G/N

  • Standards Compliance: IEC60034, GB755, BS5000, NEMA MG1-22, CSA C22.2-100, AS1359

  • Certification: ISO9001 quality management

Environmental Parameters

  • Operating Temperature: –15°C to +40°C

  • Relative Humidity: Up to 95% (non-condensing)

  • Altitude: Up to 1000 m without derating

  • Noise & Vibration: Balanced per BS6861 standards

  • Cooling Air Requirement: 0.486 m³/s @50Hz, 0.580 m³/s @60Hz

Performance Summary

  • Efficiency Range: 93.5–94.2% across load range

  • Voltage Dip (Transient Load): ≤25% at 0.8 PF

  • Recovery Time: <0.5 seconds

  • Locked Rotor Motor Starting: >300% of rated current

  • Applications: Prime power, standby, rental, telecom, mobile power, refrigeration, and railway generator systems