[rank_math_breadcrumb]

Alternator A.R.K274D

A.R.K274D Alternator – Heavy-Duty Brushless Alternator for Continuous and Standby Power Systems

The A.R.K274D alternator, manufactured by Arken Power Solutions, is a three-phase brushless synchronous alternator engineered for industrial, rental, and standby power generation. With its self-excited AVR system (SX460 standard, SX440 optional), it provides ±1% voltage regulation, THD below 5%, and efficiency up to 91.6%. Designed with Class H insulation, IP23 protection, and dynamically balanced rotor, it ensures durability and reliable performance under demanding conditions. Complying with IEC60034, BS5000, VDE0530, NEMA MG1-22, and ISO9001, it is suitable for applications such as rental, telecom, mobile, railway, refrigeration, and standby generator systems.

Alternator Model

A.R.K274D

50Hz (kVA)

120

60Hz (kVA)

137.5
Control SystemSELF EXCITED
A.V.R. OPTIONAL SX440
Voltage Regulation ± 1.0 %
Sustained Short Circuit >300% OF RATED CURRENT
Rated Power Factor0.8

Electrical Performance

  • Type: Three-phase, brushless, self-excited synchronous alternator

  • Frequency: 50 / 60 Hz

  • Power Factor: 0.8

  • Rated Voltage Range: 190–480 V (reconfigurable for star, delta, or parallel star connection)

  • Voltage Regulation: ±1.0%

  • Total Harmonic Distortion (THD): <5% (balanced load), <1.5% (no-load)

  • Sustained Short Circuit Current: >300% of rated current

  • Efficiency: Up to 91.6% depending on load and voltage

  • Telephone Harmonic Factor (THF): <2%

  • Telephone Interference Factor (TIF): <50

  • Excitation System: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 / AS440 optional, MX341 / MX321 (PMG optional)

  • Short Circuit Ratio (1/Xd): 6.0 typical

Reactances (Per Unit, Saturated)

  • Xd (Synchronous): 2.06–2.52

  • X’d (Transient): 0.16–0.21

  • X’’d (Subtransient): 0.10–0.15

  • Xq (Quadrature): 1.17–1.49

  • X’’q (Quadrature Subtransient): 0.14–0.21

  • X₂ (Negative Sequence): 0.12–0.17

  • X₀ (Zero Sequence): 0.07–0.10

  • Leakage Reactance (XL): 0.06–0.07

  • Time Constants:

    • Transient (T’d): 0.031 s

    • Subtransient (T’’d): 0.01 s

    • Open Circuit Field (T’do): 0.85 s

    • Armature (Ta): 0.0073 s

Construction & Design

  • Insulation Class: H (125°C rise at 40°C ambient)

  • Protection: IP23 (optional IP44 with 5–10% derating)

  • Cooling: Self-ventilated air cooling

    • 50 Hz: 0.514 m³/s (1090 cfm)

    • 60 Hz: 0.617 m³/s (1308 cfm)

  • Frame: Steel structure with cast aluminum front and rear covers

  • Stator: Double-layer winding with auxiliary winding, 2/3 pitch eliminates triple harmonics

  • Rotor: Damped cage rotor, dynamically balanced to BS6861 standards

  • Bearings:

    • Drive End: 6315-2RS (ISO, sealed-for-life)

    • Non-Drive End: 6310-2RS (ISO, sealed-for-life)

  • Overspeed Capability: 120% of rated speed (2250 rpm)

  • Leads: 12 reconnectable leads (series star, parallel star, or delta)

  • Stator Resistance: 0.038 Ω/phase (22°C, series star connection)

  • Rotor Resistance: 1.26 Ω (22°C)

  • Rotor Inertia (WR²): 1.1962 kg·m² (single bearing) / 1.1455 kg·m² (double bearing)

Dimensions & Weight

  • Wound Rotor Weight: 149.37 kg (single bearing) / 122.82 kg (double bearing)

  • Wound Stator Weight: 141 kg

  • Complete Alternator Weight: 431 kg (single bearing) / 450 kg (double bearing)

  • Shipping Weight: 458–476 kg (crated)

  • Packing Dimensions: 105 × 67 × 103 cm

Regulation & Control

  • Excitation: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 / AS440 / MX341 / MX321 optional

  • Voltage Regulation Accuracy: ±1.0%

  • Parallel Operation: Supported (AVR-dependent)

  • RFI Suppression: BS EN 61000-6-2 & BS EN 61000-6-4, VDE 0875G/N compliant

  • Standards Compliance: IEC60034, GB755, BS5000, VDE0530, NEMA MG1-22, CSA C22.2-100, AS1359

  • Certification: ISO9001 Quality Management System

Environmental Parameters

  • Operating Temperature: –15°C to +40°C

  • Relative Humidity: Up to 95% (non-condensing)

  • Altitude: Up to 1000 m without derating

  • Cooling Air Requirement: 0.514–0.617 m³/s depending on frequency

  • Noise & Vibration: Balanced per BS6861 mechanical standards

Performance Summary

  • Efficiency Range: 90.8–91.6%

  • Voltage Dip (Transient Load): ≤25% at 0.8 PF

  • Recovery Time: <0.5 seconds

  • Locked Rotor Motor Starting: >300% rated current

  • Applications: Prime power, standby, rental, telecom, mobile, lighting tower, refrigeration, and railway generator systems

Datasheet