A.R.K224E Alternator – Premium Brushless Alternator for Heavy-Duty and Standby Applications

The A.R.K224E alternator, designed by Arken Power Solutions, is a three-phase brushless synchronous alternator engineered for durability and performance in industrial, rental, and standby generator systems. Featuring a self-excited AVR-regulated system (SX460 standard, SX440 optional), it ensures ±1% voltage regulation, THD below 5%, and efficiency up to 90%. Built with Class H insulation, IP23 protection, and high mechanical balance, it delivers stable and clean power output even under dynamic load conditions. The alternator fully complies with IEC60034, BS5000, NEMA MG1-22, VDE0530, and ISO9001 standards, making it ideal for continuous and standby power generation across critical applications such as telecom, construction, railway, and lighting towers.

Alternator Model

A.R.K224E

50Hz (kVA)

60

60Hz (kVA)

70
Control SystemSELF EXCITED
A.V.R. OPTIONAL SX440
Voltage Regulation ± 1.0 %
Sustained Short Circuit>300% OF RATED CURRENT
Rated Power Factor0.8

Electrical Performance

  • Type: Three-phase, brushless, self-excited synchronous alternator

  • Frequency: 50 / 60 Hz

  • Power Factor: 0.8

  • Rated Power (50 Hz): 53–63 kVA (depending on voltage and configuration)

  • Rated Power (60 Hz): 60–80 kVA (depending on voltage and configuration)

  • Voltage Range: 190–480 V (configurable in series star, parallel star, or delta)

  • Voltage Regulation: ±1.0%

  • Total Harmonic Distortion (THD): <5% (balanced linear load), <1.5% (no-load)

  • Sustained Short Circuit Current: >300% of rated current

  • Efficiency: Up to 90%

  • Telephone Harmonic Factor (THF): <2%

  • Telephone Interference Factor (TIF): <50

  • Excitation System: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 optional, MX341 or MX321 (with PMG optional)

  • Short Circuit Ratio (1/Xd): 6.0 typical

Reactances (Per Unit, Saturated)

  • Xd (Synchronous): 2.08–3.00

  • X’d (Transient): 0.16–0.22

  • X’’d (Subtransient): 0.10–0.15

  • Xq (Quadrature): 0.95–1.38

  • X’’q (Quadrature Subtransient): 0.12–0.14

  • X₂ (Negative Sequence): 0.11–0.14

  • X₀ (Zero Sequence): 0.09–0.11

  • Leakage Reactance (XL): 0.07–0.09

  • Time Constants:

    • Transient (T’d): 0.028 s

    • Subtransient (T’’d): 0.007 s

    • Armature (Ta): 0.006 s

    • Open Circuit Field (T’do): 0.7 s

Construction & Design

  • Insulation Class: H (125°C rise at 40°C ambient)

  • Protection: IP23 (optional IP44 with 5–10% derating)

  • Cooling: Self-ventilated air cooling

    • 50 Hz: 0.216 m³/s (458 cfm)

    • 60 Hz: 0.281 m³/s (595 cfm)

  • Frame: High-strength steel structure with cast aluminum front and rear covers

  • Stator: Double-layer winding with auxiliary winding, 2/3 pitch eliminates triple harmonics

  • Rotor: Damped cage rotor, dynamically balanced per BS6861 standards

  • Bearings:

    • Drive End: 6315-2RS (ISO, sealed-for-life)

    • Non-Drive End: 6310-2RS (ISO, sealed-for-life)

  • Overspeed Capability: 120% of rated speed (2250 rpm)

  • Leads: 12 reconnectable leads (star, delta, or parallel star)

  • Stator Resistance: 0.101 Ω/phase (22°C, star connection)

  • Rotor Resistance: 0.69 Ω (22°C)

  • Rotor Inertia (WR²): 0.4999 kg·m² (single bearing) / 0.4682 kg·m² (double bearing)

Dimensions & Weight

  • Wound Rotor Weight: 95.89 kg (single bearing) / 87.52 kg (double bearing)

  • Wound Stator Weight: 103 kg

  • Complete Alternator Weight: 331–330 kg

  • Shipping Weight: 334–351 kg (crated)

  • Packing Dimensions: 105 × 57 × 96 cm

Regulation & Control

  • Excitation: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 / AS440 / MX341 / MX321 optional

  • Voltage Regulation Accuracy: ±1.0%

  • Parallel Operation: Supported (AVR-dependent)

  • RFI Suppression: BS EN 61000-6-2 & BS EN 61000-6-4, VDE 0875G/N compliant

  • Standards Compliance: IEC60034, GB755, BS5000, VDE0530, NEMA MG1-22, CSA C22.2-100, AS1359

  • Certification: ISO9001 Quality Management System

Environmental Parameters

  • Operating Temperature: –15°C to +40°C

  • Relative Humidity: Up to 95% (non-condensing)

  • Altitude: Up to 1000 m without derating

  • Cooling Air Requirement: 0.216–0.281 m³/s depending on frequency

  • Noise & Vibration: Balanced per BS6861 mechanical standards

Performance Summary

  • Efficiency Range: 88.0–90.0%

  • Voltage Dip (Transient Load): ≤25% at 0.8 PF

  • Recovery Time: <0.5 seconds

  • Locked Rotor Motor Starting: >300% rated current

  • Applications: Prime power, standby, rental, telecom, mobile, lighting tower, refrigeration, and railway generator systems