Alternator A.R.K224C

A.R.K224C Alternator – Heavy-Duty Brushless Alternator for Industrial and Standby Applications

The A.R.K224C alternator, engineered by Arken Power Solutions, is a three-phase brushless synchronous alternator designed to deliver stable and efficient power across industrial, rental, and continuous-duty generator systems. It features a self-excited AVR-regulated system (SX460 standard, SX440 optional) ensuring ±1% voltage regulation, THD below 5%, and efficiency up to 88.6%. With Class H insulation, IP23 protection, and a durable steel structure, the A.R.K224C combines strength, performance, and reliability. Fully compliant with IEC60034, BS5000, NEMA MG1-22, and ISO9001, this alternator is built to operate efficiently in demanding environments, providing consistent output for industrial and standby power applications.

Alternator Model

A.R.K224C

50Hz (kVA)

42.5

60Hz (kVA)

52.5
Control System SELF EXCITED
A.V.R. OPTIONAL SX440
Voltage Regulation ± 1.0 %
Sustained Short Circuit >300% OF RATED CURRENT
Rated Power Factor0.8

Electrical Performance

  • Type: Three-phase, brushless, self-excited synchronous alternator

  • Frequency: 50 / 60 Hz

  • Power Factor: 0.8

  • Voltage Range: 190–480 V (configurable in series star, parallel star, or delta)

  • Voltage Regulation: ±1.0%

  • Total Harmonic Distortion (THD): <5% (balanced load), <1.5% (no-load)

  • Sustained Short Circuit Current: >300% of rated current

  • Efficiency: Up to 88.6% depending on load and voltage

  • Telephone Harmonic Factor (THF): <2%

  • Telephone Interference Factor (TIF): <50

  • Excitation System: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 (optional), MX341 or MX321 (with PMG, optional)

  • Short Circuit Ratio (1/Xd): 6.0 typical

Reactances (Per Unit, Saturated)

  • Xd (Synchronous): 2.19–3.03

  • X’d (Transient): 0.16–0.22

  • X’’d (Subtransient): 0.10–0.15

  • Xq (Quadrature): 1.01–1.40

  • X’’q (Quadrature Subtransient): 0.13–0.16

  • X₂ (Negative Sequence): 0.12–0.14

  • X₀ (Zero Sequence): 0.08–0.10

  • Leakage Reactance (XL): 0.07–0.10

  • Time Constants:

    • Transient (T’d): 0.025 s

    • Subtransient (T’’d): 0.006 s

    • Armature (Ta): 0.005 s

    • Open Circuit Field (T’do): 0.65 s

Construction & Design

  • Insulation Class: H (125°C rise at 40°C ambient)

  • Protection: IP23 (optional IP44 with 5–10% derating)

  • Cooling: Self-ventilated air cooling

    • 50 Hz: 0.216 m³/s (458 cfm)

    • 60 Hz: 0.281 m³/s (595 cfm)

  • Frame: Steel structure with cast aluminum front and rear covers

  • Stator: Double-layer winding, 2/3 pitch eliminates triple harmonics

  • Rotor: Damped cage rotor, dynamically balanced per BS6861 standards

  • Bearings:

    • Drive End: 6315-2RS (sealed-for-life)

    • Non-Drive End: 6310-2RS (sealed-for-life)

  • Overspeed Capability: 120% of rated speed (2250 rpm)

  • Leads: 12 reconnectable leads (star, delta, or parallel star)

  • Stator Resistance: 0.181 Ω/phase (22°C, star connection)

  • Rotor Resistance: 0.59 Ω (22°C)

  • Rotor Inertia (WR²): 0.3667 kg·m² (two-bearing) / 0.3987 kg·m² (single-bearing)

Dimensions & Weight

  • Wound Rotor Weight: 70.58 kg (two-bearing) / 78.95 kg (single-bearing)

  • Wound Stator Weight: 75 kg

  • Complete Alternator Weight: 280 kg (two-bearing) / 271 kg (single-bearing)

  • Shipping Weight: 294–301 kg (crated)

  • Packing Dimensions: 95–97 × 57 × 96 cm

Regulation & Control

  • Excitation: Self-excited, AVR-controlled

  • AVR Models: SX460 (standard), SX440 / MX341 / MX321 optional

  • Voltage Regulation Accuracy: ±1.0%

  • Parallel Operation: Supported (AVR-dependent)

  • RFI Suppression: BS EN 61000-6-2 & BS EN 61000-6-4, VDE 0875G/N compliant

  • Standards Compliance: IEC60034, GB755, BS5000, VDE0530, NEMA MG1-22, CSA C22.2-100, AS1359

  • Certification: ISO9001 Quality Management System

Environmental Parameters

  • Operating Temperature: –15°C to +40°C

  • Relative Humidity: Up to 95% (non-condensing)

  • Altitude: Up to 1000 m without derating

  • Cooling Air Requirement: 0.216–0.281 m³/s depending on frequency

  • Noise & Vibration: Balanced per BS6861 mechanical standards

Performance Summary

  • Efficiency Range: 86.6–88.6%

  • Voltage Dip (Transient Load): ≤25% at 0.8 PF

  • Recovery Time: <0.5 seconds

  • Locked Rotor Motor Starting: >300% rated current

  • Applications: Prime power, standby, rental, telecom, mobile, lighting tower, refrigeration, and railway generator systems

Datasheet